Email us [email protected]. Exact matches only. Search in title. Search in content. Search in excerpt. Air Circuit breaker. Bilge Monitors. Dynamic Positioning systems. Electric Positioner. Engine Control and Alarm systems. Fire amp Gas Detection. Flow Meter. Fuel Governor Systems. Hydraulic Equipment. Level Measuring Instrument. Marine Clock. Marine Lights. Marine Printers. Speed Sensor X Fault Indicates a speed sensor failure latched.
Page Chapter 3. The Load reference ramp will follow the Remote Base-Load setpoint input until either the Unload setpoint is reached or any of the Load-Limits have been reached. The LSL's shall be daisy chained from each engine control to an other.
When this timer expires, the speed override is removed from both speed sensors. When speed is still below the minimum speed threshold, a major alarm will shutdown the engine, indicating this startup attempt has failed. Page Synchronizing The Load limiter input is not a true fuel limiter, since it does not operate on the LSS bus directly. It limits the Load reference ramp, and therefore is only active in Load control mode. Page Chapter 4.
When 5 is selected. There will be a signal failure when the Modbus communication fails. When 9 is selected. Page 35 Reset on Start Automatically issue Reset command on engine starting. Reset on Stop Automatically issue Reset command on engine stopping. Enable Auto Reset Control issues Reset commands automatically. Auto Reset Time [s] Repetition time for the automatic Reset pulse feature. Page 44 These features can be used to optimize the PID settings while running the engine in a steady state condition.
Stop Speed Setpoint [rpm] When the engine speed drops below this threshold for 5 seconds, the engine is considered stopped and only now it is possible to reset major alarms. Page 46 This is the speed reference rate when going from Idle to Rated speed by either contact input or start sequence.
Page 47 Defines the 4-point start fuel limit curve. Engine speed is the input to this curve and each next speed point shall be higher than the previous speed point.
Page 48 Sets the actuator limit during the activation of the KickDown function. Page 49 Defines the absolute maximum actuator position for this engine, active in droop and in isochronous load sharing mode. This can be the EngLoad input signal, but also the actuator based calculated backup load when the EngLoad input has failed or is not configured.
Page 53 Set Download Mode? Page Chapter 5. Page Figure A. Functional Block Diagram Woodward Page Figure B. Page Figure C. Page Chapter 6. Page Chapter 7. Product Service Options Depending on the type of product, the following options for servicing Woodward products may be available through your local Full-Service Distributor or the OEM or Packager of the equipment system.
Page Engineering Services Field Service engineering on-site support is available, depending on the product and location, from one of our Full-Service Distributors. The field engineers are experienced both on Woodward products as well as on much of the non- Woodward equipment with which our products interface. Page 70 Email and Website—www.